Accuracy of Point-of-Care B-Line Lung Ultrasound in Comparison to NT-ProBNP for Screening Acute Heart Failure

Autor: E. Glöckner, M. Christ, F. Geier, P. Otte, U. Thiem, S. Neubauer, V. Kohfeldt, K. Singler
Jazyk: angličtina
Rok vydání: 2016
Předmět:
Zdroj: Ultrasound International Open, Vol 02, Iss 03, Pp E90-E92 (2016)
Druh dokumentu: article
ISSN: 2509-596X
2199-7152
DOI: 10.1055/s-0042-108343
Popis: Aim: The objective of this pilot study was to determine the accuracy of point-of-care B-line lung ultrasound in comparison to NT Pro-BNP for screening acute heart failure. Materials and Methods: An 8-zone lung ultrasound was performed by experienced sonographers in patients presenting with acute dyspnea in the ED. AHF was determined as the final diagnosis by 2 independent reviewers. Results: Contrary to prior studies, B-line ultrasound in our study was highly specific, but moderately sensitive for identifying patients with AHF. There was a strong association between elevated NT-proBNP levels and an increased number of B-lines. Conclusion: In conclusion, point-of-care lung ultrasound is a helpful tool for ruling in or ruling out important differential diagnoses in ED patients with acute dyspnea.
Databáze: Directory of Open Access Journals