Popis: |
A synthetic jet piezo (PE) pump with an inlet channel structured akin to a diffuser/nozzle, featuring smoothed walls, was developed. The synthetic jet was characterized by analyzing the internal flow field of the PE pump. Furthermore, the flow performance of this novel PE pump was compared with that of a basic PE pump, thereby demonstrating the advantages of the proposed design. Utilizing regression equations and standardized effect plots derived from the response surface method, both the main and interaction effects of parameters on the flow rate were assessed. Subsequently, the flow performance of the optimized PE pump was evaluated through experimental testing. Additionally, air impact cooling experiments were conducted, focusing on the influence of the impact distance on cooling performance. The findings indicated that the PE pump's open cavity height, closed cavity height, outlet diameter, and orifice diameter were 1.3 mm, 0.5 mm, 1.5 mm, and 0.8 mm, respectively. The proposed synthetic jet PE pump achieved a flow rate of 1832.3 ml/min at 50 Vpp and 4.6 kHz. Furthermore, it was observed that the operation of the PE pump reduced the temperature of the heater by 63 % at an impact distance of 20 mm. |