The Korean Version of the Fugl-Meyer Assessment: Reliability and Validity Evaluation

Autor: Tae-lim Kim, Sung Hwan Hwang, Wang Jae Lee, Jae Woong Hwang, Inyong Cho, Eun-Hye Kim, Jung Ah Lee, Yujin Choi, Jin Ho Park, Joon-Ho Shin
Jazyk: angličtina
Rok vydání: 2021
Předmět:
Zdroj: Annals of Rehabilitation Medicine, Vol 45, Iss 2, Pp 83-98 (2021)
Druh dokumentu: article
ISSN: 2234-0645
2234-0653
DOI: 10.5535/arm.20225
Popis: Objective To systematically translate the Fugl-Meyer Assessment (FMA) into a Korean version of the FMA (K-FMA). Methods We translated the original FMA into the Korean version with three translators and a translation committee, which included physiatrists, physical therapists, and occupational therapists. Based on a test-retest method, each of 31 patients with stroke was assessed by two evaluators twice, once on recruitment, and again after a week. Analysis of intra- and inter-rater reliabilities was performed using the intra-class correlation coefficient, whereas validity was analysed using Pearson correlation test along with the Motricity Index (MI), Motor Assessment Scale (MAS), and Berg Balance Scale (BBS). Results The intra- and inter-rater reliabilities were significant for the total score, and good to excellent reliability was noted in all domains except for the joint range of motion of the lower extremity domain of the K-FMA. The MI and MAS scores were significantly correlated with all domains, all with p