Development and Validation of a Risk‐Prediction Nomogram for Preoperative Blood Type and Antibody Testing in Spinal Fusion Surgery
Autor: | Linghong Wu, Xiaozhong Peng, Xianglong Zhuo, Guangwei Zhu, Xiangtao Xie |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2024 |
Předmět: | |
Zdroj: | Orthopaedic Surgery, Vol 16, Iss 1, Pp 111-122 (2024) |
Druh dokumentu: | article |
ISSN: | 1757-7861 1757-7853 |
DOI: | 10.1111/os.13946 |
Popis: | Objective With advancements in minimally invasive techniques, the use of spinal fusion surgery is rapidly increasing and transfusion rates are decreasing. Routine preoperative ABO/Rh blood type and antibody screening (T&S) laboratory tests may not be appropriate for all spinal fusion patients. Herein, we constructed a nomogram to assess patient transfusion risk based on various risk factors in patients undergoing spinal fusion surgery, so that preoperative T&S testing can be selectively scheduled in appropriate patients to reduce healthcare and patient costs. Methods Patients who underwent spinal fusion surgery between 01/2020 and 03/2023 were retrospectively examined and classified into the training (n = 3533, 70%) and validation (n = 1515, 30%) datasets. LASSO and multivariable logistic regression were used to analyze risk factors for blood transfusion. Nomogram predictive model was built according to the independent predictors and mode predictive power was validated using consistency index (C‐index), Hosmer–Lemeshow (HL) test, calibration curve analysis and area under the curve (AUC) for receiver operating characteristic (ROC) curve. Bootstrap resampling was used for internal validation. Decision curve analysis (DCA) was applied to evaluate the model's performance in the clinic. Results Being female, age, BMI, admission route, critical patient, operative time, heart failure, end‐stage renal disease or chronic kidney disease (ESRD or CKD), anemia, and coagulation defect were predictors of blood transfusion for spinal fusion. A prediction nomogram was developed according to a multivariate model with good discriminatory power (C‐index = 0.887); Bootstrap resampling internal validation C‐index was 0.883. Calibration curves showed strong matching between the predicted and actual probabilities of the training and validation sets. HL tests for the training and validation sets had p‐values of 0.327 and 0.179, respectively, indicating good calibration. When applied to the training set, the following parameters were found: AUC: 0.895, 95% CI: 0.871–0.919, sensitivity 78.2%, specificity 86.7%, positive predictive value 29.4% and negative predictive value 98.2%. If the model were applied in the training set, 2911 T&S tests (82.4%) would be eliminated, equaling a RMB349,320 cost reduction. The AUC in the internal validation was: 0.879, 95% CI: 0.839–0.927, sensitivity 75.2%, specificity 88.8%, positive predictive value 34.3%, negative predictive value 97.9%, would eliminate 1276 T&S tests (84.2%), saving RMB 153,120. The DCA curve indicated good clinical application value. Conclusion The nomogram based on 10 independent factors can help healthcare professionals predict the risk of transfusion for patients undergoing spinal fusion surgery to target preoperative T&S testing to appropriate patients and reduce healthcare costs. |
Databáze: | Directory of Open Access Journals |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |