Therapeutic effect of long-acting muscarinic antagonist for treating uncontrolled asthma assessed using impulse oscillometry

Autor: Hiroyuki Sugawara, Atsushi Saito, Saori Yokoyama, Hirofumi Chiba
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Respiratory Research, Vol 25, Iss 1, Pp 1-11 (2024)
Druh dokumentu: article
ISSN: 1465-993X
DOI: 10.1186/s12931-024-02921-z
Popis: Abstract Background In recent years, the incorporation of LAMAs into asthma therapy has been expected to enhance symptom control. However, a significant number of patients with asthma continue to experience poorly managed symptoms. There have been limited investigations on LAMA-induced airway alterations in asthma treatment employing IOS. In this study, we administered a LAMA to patients with poorly controlled asthma, evaluated clinical responses and respiratory function, and investigated airway changes facilitated by LAMA treatments using the IOS. Methods Of a total of 1282 consecutive patients with asthma, 118 exhibited uncontrolled symptoms. Among them, 42 switched their treatment to high-dose fluticasone furoate/umeclidinium/vilanterol (FF/UMEC/VI) (ICS/LABA/LAMA). The patients were then assessed using AHQ-33 or LCQ and ACT. Spirometry parameters (such as FEV1 or MMEF) and IOS parameters (such as R20 or AX) were measured and compared before and after exacerbations and the addition of LAMA. Results Of the 42 patients, 17 who switched to FF/UMEC/VI caused by dyspnea exhibited decreased pulmonary function between period 1 and baseline, followed by an increase in pulmonary function between baseline and period 2. Significant differences were observed in IOS parameters such as R20, R5-R20, Fres, or AX between period 1 and baseline as well as between baseline and period 2. Among the patients who switched to inhaler due to cough, 25 were classified as responders (n = 17) and nonresponders (n = 8) based on treatment outcomes. Among nonresponders, there were no significant differences in spirometry parameters such as FEV1 or PEF and IOS parameters such as R20 or AX between period 1 and baseline. However, among responders, significant differences were observed in all IOS parameters, though not in most spirometry parameters, between period 1 and baseline. Furthermore, significant differences were noted between baseline and period 2 in terms of FEV1, %MMEF, %PEF, and all IOS parameters. Conclusion ICS/LABA/LAMA demonstrates superiority over ICS/LABA in improving symptoms and lung function, which is primarily attributed to the addition of LAMA. Additionally, IOS revealed the effectiveness of LAMA across all airway segments, particularly in the periphery. Hence, LAMA can be effective against various asthma phenotypes characterized by airway inflammation, even in real-world cases.
Databáze: Directory of Open Access Journals
Nepřihlášeným uživatelům se plný text nezobrazuje