Tensile Strength of Modified 4-Strand Cruciate Technique for Transversely or Obliquely Lacerated Tendons

Autor: MH Yuen, WY Ip
Jazyk: angličtina
Rok vydání: 2007
Předmět:
Zdroj: Journal of Orthopaedic Surgery, Vol 15 (2007)
Druh dokumentu: article
ISSN: 2309-4990
23094990
DOI: 10.1177/230949900701500107
Popis: Purposes. To assess the tensile strength of the modified 4-strand cruciate technique for obliquely lacerated tendons, and to compare the findings with the strength of transversely lacerated tendons repaired at various grasping depths. Methods. 60 porcine front foot tendons were evenly divided into 4 groups. In groups 1 to 3, tendons were transversely lacerated and repaired with grasping points at both ends away from the laceration by 5 mm, 10 mm, and 15 mm respectively. In group 4, tendons were obliquely lacerated and repaired with a grasping point 5 mm away from the laceration on one end and 15 mm on the other. All tendons were repaired with a modified 4-strand core suture and continuous epitendinous suture, and then tested to failure in a tensile machine. Results. The tensile strength in group 1 was significantly lower than that in the other 3 groups (p