Autologous rectus abdominis fascia sling surgery following unsuccessful synthetic midurethral sling

Autor: Yoshitaka Kurano, Nobutaka Shimizu, Rie Yoshimura, Ryohei Iga, Kaya Atagi, Tomoya Nao, Hideo Fukuhara, Satoshi Fukata, Shingo Ashida, Keiji Inoue
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: IJU Case Reports, Vol 7, Iss 3, Pp 259-261 (2024)
Druh dokumentu: article
ISSN: 2577-171X
DOI: 10.1002/iju5.12719
Popis: Introduction We performed autologous rectus abdominis fascia sling surgery using Advantage™ following an unsuccessful synthetic midurethral sling. Case presentation At the age of 76 years, the patient experienced stress urinary incontinence recurrence. A 1‐h pad test resulted in 259 g of leakage. A pressure flow study verified urine leakage while coughing and straining without detrusor overactivity. Abdominal leak point pressure was 10 cmH2O. Autologous rectus abdominis fascia sling surgery was performed using Advantage™. One month postoperatively, a 1‐h pad test resulted in 0 g of leakage. Conclusion We believe that this method will allow the fascia sling procedure to be performed reliably even if one is unfamiliar with conventional autologous rectus abdominis fascia sling surgery.