A 3D printing personalized percutaneous puncture guide access plate for percutaneous nephrolithotomy: a pilot study

Autor: Gao Keyu, Li Shuaishuai, Ashok Raj, Li Shuofeng, Liu Shuai, Zhang Yuan, Zhu Haitao, Wang Junqi
Jazyk: angličtina
Rok vydání: 2021
Předmět:
Zdroj: BMC Urology, Vol 21, Iss 1, Pp 1-6 (2021)
Druh dokumentu: article
ISSN: 1471-2490
DOI: 10.1186/s12894-021-00945-x
Popis: Abstract Objective CT-Urography combined with 3D printing technology, digital design, construction of individualized PCNL puncture guides, and preliminary analyze their efficacy, safety puncture positioning for PCNL. Methods Twenty-two patients with renal calculi were randomly selected at the affiliated Hospital of Xuzhou Medical University during 2017–2018. We randomly divided the patients into two groups: in 10 experimental groups, we used our 3D printing personalized percutaneous puncture guide access plate for PCNL, and in the control group, 12 patients with standard USG guide PCNL. The accuracy of puncture position, puncture time, and intraoperative blood loss was compared. Results In the experimental group, 10 patients with 3D printing personalized percutaneous puncture guide access plate. The puncture needle was accessed through the guide plate and verified by the color Doppler. The single puncture, needle position, and depth success rate were 100.00% (10/10). The angles were consistent with the preoperative design. In the control group, 12 patients via USG guided PCNL success rate was 75.00% (9/12). The puncture time and amount of hemorrhage was (7.78 ± 0.94) min and (49.31 ± 6.43) mL, and (9.04 ± 1.09) min and (60.08 ± 12.18) mL, respectively. The above data of the two groups were statistically significant (P
Databáze: Directory of Open Access Journals