Contribution of pulse oximetry in relation to respiratory flow events in a home-based approach aimed at diagnosing obstructive sleep apnea
Autor: | Eduardo Enrique Borsini, Magali Blanco, Glenda Ernst, Alejandro Salvado, Ignacio Bledel, Carlos Alberto Nigro |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: | |
Zdroj: | Sleep Science, Vol 14, Iss 1, Pp 77-81 (2021) |
Druh dokumentu: | article |
ISSN: | 1984-0659 1984-0063 |
DOI: | 10.5935/1984-0063.20200042 |
Popis: | Objective: To compare pulse oximetry with manual analysis against all signals of respiratory polygraphy. Material and Methods: This retrospective study estimated sensitivity (S), specificity (Sp) and positive/negative likelihood ratio (LR+/-) of the oxygen desaturation index (ODI-test) and apnea-hypopnea index (AHI-reference). Results: 3854 patients (61.5% men) were included. Age, BMI, Epworth sleepiness scale and AHI were: 55 years (44-65), 30.9kg/m2 (27-36), 7 points (4-11), and 14 events/hour (6-25), respectively. 18% showed an AHI 15 and < 30, and 31% > 30. The S, Sp, and LR+/- of ODI for AHI = 5 events/hour was 93%, 92%, 12 and 0.08 with an accuracy of 93%. For AHI = 15 events/hour, the values were: S 94%, Sp 94%, LR+ 15 and LR- 0.06 and 94% accuracy (r2 Spearman: 0.92). Conclusion: In a population at a high risk for OSA, home-based pulse oximetry had a diagnostic accuracy > 90% when is compared against all respiratory signals obtained from simplified home sleep testing. |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |