Autor: |
Amariel E. Barra, Carlos Barrios |
Jazyk: |
angličtina |
Rok vydání: |
2024 |
Předmět: |
|
Zdroj: |
Frontiers in Surgery, Vol 11 (2024) |
Druh dokumentu: |
article |
ISSN: |
2296-875X |
DOI: |
10.3389/fsurg.2024.1438858 |
Popis: |
IntroductionCut-out, a biomechanical complication, is one of the most common causes of internal fixation failure of trochanteric hip fractures. The tip-apex distance (TAD) and the calcar-referenced tip-apex distance (CalTAD) have been suggested as the radiographic parameters that most predict the risk of cut-out. The purpose of this study was to check whether these two factors could predict implant cut-out in a series 398 of intertrochanteric hip fractures, treated by dynamic intramedullary nailing with the Trigen Intertan short nail.MethodsWe reviewed 398 consecutive intertrochanteric fractures included in a prospective study and treated in a single private hospital by the same surgeon. The radiographic parameters were obtained from anteroposterior (AP) and axial hip plain radiographs before surgery, immediately postoperatively, and every 3 weeks after surgery until 3 months postoperatively, and every month until the 6-month follow-up. The concept of medial cortex support (MCS) was also analyzed as a criterion for evaluating the quality of fracture reduction.ResultsThe overall cut-out rate was 2.3% (9/398). The significant parameters in the univariate analysis were AO fracture type, quality of fracture reduction (p = 0.02), TAD (p 25 mm reduced the occurrence of cut-out after dynamic intramedullary nailing of intertrochanteric fractures. |
Databáze: |
Directory of Open Access Journals |