Autor: |
Mareike Hummert, Paul Leenders, Alexander Mellmann, Karsten Becker, Thorsten Kuczius |
Jazyk: |
angličtina |
Rok vydání: |
2023 |
Předmět: |
|
Zdroj: |
Plasma, Vol 6, Iss 4, Pp 699-713 (2023) |
Druh dokumentu: |
article |
ISSN: |
2571-6182 |
DOI: |
10.3390/plasma6040048 |
Popis: |
The application of the non-thermal atmospheric pressure plasma technology is a promising tool for microbial inactivation. During the activation process, many reactive substances and radicals arise associated with physicochemical changes in the fluid and massive pH drop. In this study, we analyzed and optimized plasma activation settings and conditions of water and liquids to obtain inactivation of the waterborne microorganism Pseudomonas aeruginosa in a liquid environment. The minimal electrical output was 60 Watt with 20 min activation time followed by 30 min contact time with 108 cells/mL. Using higher electrical power (>90 W) with a Lab Unit generating plasma-activated water, a shorter activation time ( |