Autor: |
Robalinho Paulo, Rodrigues A., Novais S., Ribeiro A. B. Lobo, Silva S., Frazão O. |
Jazyk: |
angličtina |
Rok vydání: |
2023 |
Předmět: |
|
Zdroj: |
EPJ Web of Conferences, Vol 287, p 09039 (2023) |
Druh dokumentu: |
article |
ISSN: |
2100-014X |
DOI: |
10.1051/epjconf/202328709039 |
Popis: |
White Light Interferometry, known for its absolute measurement capability and high precision, had its greatest scientific impact towards the end of the 20th century. In this work, it was assembled and characterized a fibre Mach-Zehnder interferometer (MZI) as an interrogator and a fibre Fabry-Perot interferometer (FPI) as a displacement sensor. A measurement bandwidth between 65 μm and 95 μm was obtained for FPI cavities close to 2.35 mm, at sampling frequencies between 600 Hz and 1500 Hz. Additionally, a resonant frequency at 550 Hz was achieved, allowing for an interrogation band higher than 135 μm. It was also determined a minimum absolute resolution of ± 66 nm, corresponding to a relative resolution of ± 9.4×10-4 in relation to the total band. |