Abdominal CT: a radiologist-driven adjustment of the dose of iodinated contrast agent approaches a calculation per lean body weight

Autor: Moreno Zanardo, Fabio Martino Doniselli, Anastassia Esseridou, Stefania Tritella, Chiara Mattiuz, Laura Menicagli, Giovanni Di Leo, Francesco Sardanelli
Jazyk: angličtina
Rok vydání: 2018
Předmět:
Zdroj: European Radiology Experimental, Vol 2, Iss 1, Pp 1-7 (2018)
Druh dokumentu: article
ISSN: 2509-9280
DOI: 10.1186/s41747-018-0074-1
Popis: Abstract Background The contrast agent (CA) dose for abdominal computed tomography (CT) is typically based on patient total body weight (TBW), ignoring adipose tissue distribution. We report on our experience of dosing according to the lean body weight (LBW). Methods After Ethics Committee approval, we retrospectively screened 219 consecutive patients, 18 being excluded for not matching the inclusion criteria. Thus, 201 were analysed (106 males), all undergoing a contrast-enhanced abdominal CT with iopamidol (370 mgI/mL) or iomeprol (400 mgI/mL). LBW was estimated using validated formulas. Liver contrast-enhancement (CEL) was measured. Data were reported as mean ± standard deviation. Pearson correlation coefficient, ANOVA, and the Levene test were used. Results Mean age was 66 ± 13 years, TBW 72 ± 15 kg, LBW 53 ± 11 kg, and LBW/TBW ratio 74 ± 8%; body mass index was 26 ± 5 kg/m2, with 9 underweight patients (4%), 82 normal weight (41%), 76 overweight (38%), and 34 obese (17%). The administered CA dose was 0.46 ± 0.06 gI/kg of TBW, corresponding to 0.63 ± 0.09 gI/kg of LBW. A negative correlation was found between TBW and CA dose (r = -0.683, p