Numerical simulation of the influence of the structural parameters of a sampling diluter for particulate matter in diesel engines on the internal flow field and dilution ratio

Autor: Limin Geng, Yang Zhao, Guifen Sheng, Nan Gao, Yonggang Xiao, Feichuang Huang, Hao Chen
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Energy Science & Engineering, Vol 12, Iss 7, Pp 2785-2797 (2024)
Druh dokumentu: article
ISSN: 2050-0505
DOI: 10.1002/ese3.1761
Popis: Abstract This study investigated how structural parameters (including injection ducts and exhaust nozzle inner diameters) affect the internal flow field and dilution ratio of diesel particulate sampling diluters. Increasing air injection duct diameter increased the injection chamber pressure and decreased the air velocity peak, mixed gas flow velocity, sample temperature, and mixing rate. Excessively small tube diameters caused uneven and discontinuous flow field distributions, while substantial air blockage rendered the flow state poor. Increasing nozzle inner diameters increased the exhaust flow area and the sample temperature, but decreased the velocity of the exhaust and gas mixtures and the pressure drop. Compared with a 2.0 mm inner diameter, 2.5 and 3.0 mm diameters decreased the peak velocity by 11.18% and 14.41%, respectively, and mixing slowed significantly. Inner nozzle diameters of