The impact of pneumatic tube transport on whole blood coagulation and platelet function assays

Autor: Peter H. Nissen, Dorte E. Wulff, Niels Tørring, Anne-Mette Hvas
Jazyk: angličtina
Rok vydání: 2018
Předmět:
Zdroj: Platelets, Vol 29, Iss 4, Pp 421-424 (2018)
Druh dokumentu: article
ISSN: 0953-7104
1369-1635
09537104
DOI: 10.1080/09537104.2018.1430361
Popis: Pneumatic tube is an attractive way to transport blood samples from the emergency department to the central laboratory facility. We aimed to investigate the impact of pneumatic tube transportation on blood samples for analysis of whole blood coagulation and platelet function. We included 21 healthy adult individuals and measured global coagulation assays by rotational thromboelastometry (ROTEM) and platelet aggregation induced by arachidonic acid (AA) and adenosine diphosphate (ADP) using impedance aggregometry (ROTEM Platelet), on samples transported manually or by pneumatic tube transport. Statistical testing was performed with paired tests with post-hoc Bonferroni correction for multiple testing. Our data revealed no difference in the far majority of ROTEM parameters (P > 0.003), while significantly decreased values were observed for INTEM clotting time (CT) (P = 0.002) and maximum clot firmness (MCF) including the amplitude after 10 min (A10) (P 0.003). This study indicates that only minor and unsystematic differences between manual transport and pneumatic tube transport may be observed in ROTEM analyses, and that there is no influence from pneumatic tube transport on impedance aggregometry analyses using AA and ADP.
Databáze: Directory of Open Access Journals