Autor: |
Qianling Wang, Longxiang Su, Jing Jiang, Na Wang, Huaiwu He, Yun Long |
Jazyk: |
angličtina |
Rok vydání: |
2023 |
Předmět: |
|
Zdroj: |
Frontiers in Medicine, Vol 10 (2023) |
Druh dokumentu: |
article |
ISSN: |
2296-858X |
DOI: |
10.3389/fmed.2023.1240321 |
Popis: |
Pneumothorax is a potentially fatal complication in patients with acute respiratory distress syndrome (ARDS), presenting challenges in determining the optimal positive end-expiratory pressure (PEEP) level to prevent atelectasis without exacerbating the pneumothorax. This case report describes the successful application of transpulmonary pressure and electrical impedance tomography (EIT) at the bedside to guide PEEP selection in a patient with ARDS complicated by pneumothorax due to methicillin-resistant Staphylococcus aureus infection. By using minimal PEEP to maintain positive end-expiratory transpulmonary pressure and visualizing lung reopening with EIT, the optimal PEEP level was reaffirmed, even if traditionally considered high. The patient’s condition improved, and successful weaning from the ventilator was achieved, leading to a transfer out of the intensive care unit.Clinical trial registration: https://clinicaltrials.gov/show/NCT04081142, identifier NCT04081142. |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|