Left Atrial Function Post Radiofrequency and Cryoballoon Ablation Assessed by Volume-Pressure Loops

Autor: Antonios Karanasos, Konstantinos Tyrovolas, Dimitrios Tsiachris, Michalis Efremidis, Athanasios Kordalis, Maria Karmpalioti, Efstathia Prappa, Stefanos Karagiannis, Constantina Aggeli, Konstantinos Gatzoulis, Dimitrios Tousoulis, Costas Tsioufis, Konstantinos P. Toutouzas
Jazyk: angličtina
Rok vydání: 2022
Předmět:
Zdroj: Frontiers in Cardiovascular Medicine, Vol 9 (2022)
Druh dokumentu: article
ISSN: 2297-055X
DOI: 10.3389/fcvm.2022.830055
Popis: BackgroundLeft atrial (LA) function is linked to atrial fibrillation (AF) pathogenesis. AF catheter ablation decreases disease burden with potentially favorable effects on cardiac function. Atrial volume-pressure loops can optimally assess the LA function.ObjectiveTo investigate changes in LA function by volume-pressure loops after paroxysmal AF ablation and explored potential differences between the radiofrequency and cryoballoon ablation.MethodsWe analyzed 44 patients undergoing paroxysmal AF ablation from 2 centers, 22 treated with radiofrequency and 22 with cryoablation. Pre- and post-procedure, all patients underwent a real-time three-dimensional transthoracic ECG to evaluate LA volume, while simultaneously recording LA pressure following transseptal puncture. Volume-pressure loops pre- and post-procedure were created by paired data. Areas of A-loop (LA booster pump function) and V-loop (LA reservoir function), and the stiffness constant determining the slope of the exponential curve during LA filling were calculated.ResultsAverage LA pressure, A-wave amplitude, and V-wave amplitude were increased post-procedurally (p < 0.001). Overall, A-loop area decreased (p = 0.001) and V-loop area tended to increase (p = 0.07). The change in both A-loop and V-loop areas was similar between radiofrequency- and cryoballoon-treated patients (p = 0.18 and p = 0.52, respectively). However, compared with cryoballoon-treated patients, radiofrequency-treated patients had higher increase in the stiffness constant (b = 0.059; 95% CI: 0.022–0.096; p = 0.006).ConclusionAF catheter ablation by the radiofrequency or cryoballoon is associated with the decrease of the booster pump function and increase of the reservoir function. Moreover, there is a post-procedural increase of LA pressure which is associated with an acute increase in LA stiffness in radiofrequency ablation, but not in cryoablation.
Databáze: Directory of Open Access Journals