Changes in corneal epithelial thickness and optical density and their correlation after smart pulse technology-assisted transepithelial photorefractive keratectomy

Autor: Niu Shiyang, Yang Hua, Li Yan, Dai Zhiqiang, Li Xinmin, Zhou Yulan, Zhang Ouyang, Wang Baojun
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Guoji Yanke Zazhi, Vol 24, Iss 8, Pp 1308-1313 (2024)
Druh dokumentu: article
ISSN: 1672-5123
DOI: 10.3980/j.issn.1672-5123.2024.8.24
Popis: AIM: To evaluate the changes in corneal epithelial thickness(CET)and corneal optical density(CD)after smart pulse technology(SPT)-assisted transepithelial photorefractive keratectomy(TPRK)and analyze their correlation.METHODS: The prospective study included 60 patients(120 eyes)with myopia and myopic astigmatism who underwent SPT-TPRK in the ophthalmology department at the First Affiliated Hospital of Xinxiang Medical University between February and August 2023. Changes in CET and CD were evaluated preoperatively and at 1 wk, 1 and 3 mo postoperatively.RESULTS: A total of 14 cases(28 eyes)were lost to follow-up, and 3 patients(6 eyes)with postoperative haze were excluded from this study, resulting in a final inclusion of 43 patients(86 eyes). At 1 wk after SPT-TPRK, CET had statistically significantly thickened compared to preoperative levels(P