Assessing protein and albumin recovery rates in different ascites filtration membrane washing methods for cell-free and concentrated ascites reinfusion therapy
Autor: | Sachie Yamada, Norio Nii, Atsushi Ohashi, Midori Hasegawa, Yukio Yuzawa, Naotake Tsuboi |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2024 |
Předmět: | |
Zdroj: | Fujita Medical Journal, Vol 10, Iss 2, Pp 53-59 (2024) |
Druh dokumentu: | article |
ISSN: | 2189-7247 2189-7255 |
DOI: | 10.20407/fmj.2023-005 |
Popis: | Objectives: In cell-free and concentrated ascites reinfusion therapy (CART), the protein recovery rate decreases when the filtration membrane gets clogged. Employing a device with a filtration membrane washing feature prevents clogging, but it leads to the loss of ascites within the filter, resulting in reduced protein recovery. This study employed a device with a membrane washing function to investigate the relationship between protein recovery rate and the quantity of washing solution used, depending on the selected washing method. Methods: We analyzed cases of CART conducted at Fujita Health University Hospital between May 2021 and November 2022. The cases were divided and compared between two groups: one using flush and rinse as the washing method (flush+rinse group) and another using only flushing (flush group). Results: We identified nine cases and 16 sessions. In the flush+rinse group, the median amount of washing solution used per membrane washing was 259 mL per cycle, whereas it was 54 mL per cycle in the flush group. This difference was statistically significant (p |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |