Autor: |
Salima Rattani, Joveria Farooqi, Ghazala Jabeen, Saeeda Chandio, Qaiser Kash, Aijaz Khan, Kauser Jabeen |
Jazyk: |
angličtina |
Rok vydání: |
2020 |
Předmět: |
|
Zdroj: |
BMC Pulmonary Medicine, Vol 20, Iss 1, Pp 1-7 (2020) |
Druh dokumentu: |
article |
ISSN: |
1471-2466 |
DOI: |
10.1186/s12890-020-01311-7 |
Popis: |
Abstract Background Diagnosis of lower respiratory tract infections (LRTI) depends on the presence of clinical, radiological and microbiological findings. Endotracheal suction aspirate (ETSA) is the commonest respiratory sample sent for culture from intubated patients. Very few studies have compared quantitative and semi-quantitative processing of ETSA cultures for LRTI diagnosis. We determined the diagnostic accuracy of quantitative and semi-quantitative ETSA culture for LRTI diagnosis, agreement between the quantitative and semi quantitative culture techniques and the yield of respiratory pathogens with both methods. Methods This was a cross-sectional study conducted at the Aga Khan University clinical laboratory, Karachi, Pakistan. One hundred and seventy-eight ETSA samples sent for routine bacteriological cultures were processed quantitatively as part of regular specimen processing method and semi-quantitatively. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy was calculated for both methods using clinical diagnosis of pneumonia as reference standard. Agreement between the quantitative and semi quantitative methods was assessed via the kappa statistic test. Pathogen yield between the two methods was compared using Pearson’s chi-square test. Results The quantitative and semi-quantitative methods yielded pathogens in 81 (45.5%) and 85 (47.8%) cases respectively. There was complete concordance of both techniques in 155 (87.1%) ETSA samples. No growth was observed in 45 (25.3%) ETSA specimens with quantitative culture and 37 (20.8%) cases by semi-quantitative culture. The diagnostic accuracy of both techniques were comparable; 64.6% for quantitative and 64.0% for semi-quantitative culture. The kappa agreement was found to be 0.84 (95% CI, 0.77–0.91) representing almost perfect agreement between the two methods. Although semi-quantitative cultures yielded more pathogens (47.8%) as compared to quantitative ETSA cultures (45.5%), the difference was only 2.3%. However, this difference achieved statistical (chi-square p-value |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|