Autor: |
John Reza Matthews, Jiefei Wang, Jiwei Zhao, Melissa A. Kluczynski, Leslie J. Bisson |
Jazyk: |
angličtina |
Rok vydání: |
2020 |
Předmět: |
|
Zdroj: |
Knee Surgery & Related Research, Vol 32, Iss 1, Pp 1-8 (2020) |
Druh dokumentu: |
article |
ISSN: |
2234-2451 |
DOI: |
10.1186/s43019-020-00053-4 |
Popis: |
Abstract Background Repair of a meniscal tear is indicated in certain conditions. Despite extensive research on the biomechanics of various repair methods, there has been minimal investigation of whether the suture material influences the meniscal-suture construct. The purpose of this study was to compare the biomechanical properties of nine different suture materials under cyclic and load-to-failure conditions. Methods Ninety porcine menisci were randomly allocated to simple suture placement using either Ultrabraid®, Ultratape®, Magnum Wire®, TigerWire®, TigerTape®, LabralTape®, Orthocord®, 0 FiberWire®, or 2-0 FiberWire®. Each suture-meniscus specimen underwent cyclic loading followed by load-to-failure testing. Elongation, maximum load to failure, stiffness, and mode of failure were recorded and compared between each suture type using non-parametric testing. Mean ± standard deviation was reported and the statistical significance was p |