Ultrasound-guided biodegradable subacromial spacer implantation in a patient with massive irreparable rotator cuff tears

Autor: Tomasz Poboży, Maciej Kielar, Jakub Miąskiewicz
Jazyk: angličtina
Rok vydání: 2018
Předmět:
Zdroj: Videosurgery and Other Miniinvasive Techniques, Vol 14, Iss 1, Pp 145-148 (2018)
Druh dokumentu: article
ISSN: 1895-4588
2299-0054
DOI: 10.5114/wiitm.2018.77555
Popis: The aim of this manuscript is to present a modification of the current arthroscopic implantation technique of a biodegradable subacromial spacer. This modified ultrasound-guided technique was intended to maximally reduce the invasiveness of the procedure. The ultrasound technique was used to measure the subacromial space for an optimal fit and to verify subacromial spacer placement in the sagittal and frontal planes. This finding is of particular importance for patients with contraindications to general or regional anesthesia. The follow-up (5 months) of subacromial spacer implantation using ultrasound in a patient with an irreparable rotator cuff tear showed correct spacer placement.