Assessing Evapotranspiration Models for Regional Implementation in the Mediterranean: A Comparative Analysis of STEPS, TSEB, and SCOPE with Global Datasets

Autor: Zaib Unnisa, Ajit Govind, Egor Prikaziuk, Christiaan Van der Tol, Bruno Lasserre, Vicente Burchard-Levine, Marco Marchetti
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Applied Sciences, Vol 14, Iss 17, p 7685 (2024)
Druh dokumentu: article
ISSN: 2076-3417
DOI: 10.3390/app14177685
Popis: Accurate evapotranspiration (ET) estimation is crucial for sustainable water management in the diverse and water-scarce Mediterranean region. This study compares three prominent models (Simulator of Terrestrial Ecohydrological Processes and Systems (STEPS), Soil-Canopy-Observation of Photosynthesis and Energy fluxes (SCOPE), and Two-Source Energy Balance (TSEB)) with established global datasets (Moderate Resolution Imaging Spectroradiometer 8-day global terrestrial product (MOD16A2), Global Land Evaporation Amsterdam Model (GLEAM), and TerraClimate) at multiple spatial and temporal scales and validates model outcomes with eddy covariance based ground measurements. Insufficient ground-based observations limit comprehensive model validation in the eastern Mediterranean part (Turkey and Balkans). The results reveal significant discrepancies among models and datasets, highlighting the challenges of capturing ET variability in this complex region. Differences are attributed to variations in ecosystem type, energy balance calculations, and water availability constraints. Ground validation shows that STEPS performs well in some French and Italian forests and crops sites but struggles with seasonal ET patterns in some locations. SCOPE mostly overestimates ET due to detailed radiation flux calculations and lacks accurate water limitation representation. TSEB faces challenges in capturing ET variations across different ecosystems at a coarser 10 km resolution. No single model and global dataset accurately represent ET across the entire region. Model performance varies by region and ecosystem. As GLEAM and TSEB excel in semi-arid Savannahs, STEPS and SCOPE are better in grasslands, croplands, and forests in few locations (5 out of 18 sites) which indicates these models need calibration for other locations and ecosystem types. Thus, a region-specific model calibration and validation, sensitive to extremely humid and arid conditions can improve ET estimation across the diverse Mediterranean region.
Databáze: Directory of Open Access Journals