Changes in Lacrimal Punctum Position and Tear Meniscus Height after Correction of Horizontal Laxity in Involutional Lower Eyelid Entropion

Autor: Tatsuro Yokoyama, Aric Vaidya, Shinjiro Kono, Hirohiko Kakizaki, Yasuhiro Takahashi
Jazyk: angličtina
Rok vydání: 2023
Předmět:
Zdroj: Journal of Ophthalmology, Vol 2023 (2023)
Druh dokumentu: article
ISSN: 2090-0058
DOI: 10.1155/2023/4113151
Popis: Purpose. To examine changes in the position of the lower eyelid punctum and tear meniscus height (TMH) after correction of horizontal laxity of the lower eyelid in involutional lower eyelid entropion. Methods. This prospective, observational study included 42 sides of 36 patients with involutional entropion who underwent a lateral tarsal strip procedure or transcanthal canthopexy (+ lower eyelid retractor advancement). The horizontal distance from the medial margin of the lower lacrimal punctum to the medial canthus was measured using ImageJ software. TMH was measured using anterior segment optical coherence tomography. All measurements were performed preoperatively, at postoperative 3-month and at postoperative 6-month. Results. The lower lacrimal punctum significantly shifted laterally at 3-month follow-up and slightly returned toward its original position at 6-month follow-up (Friedman’s test, P
Databáze: Directory of Open Access Journals