The evaluation of ocular refractive error and axial length changes after scleral buckle removal

Autor: Ahoor M Hosein, Sorkhabi Rana, Eftekhari M Amir, Ojaghi Habib, Najafi Amin
Jazyk: angličtina
Rok vydání: 2019
Předmět:
Zdroj: Journal of Family Medicine and Primary Care, Vol 8, Iss 9, Pp 2950-2952 (2019)
Druh dokumentu: article
ISSN: 2249-4863
DOI: 10.4103/jfmpc.jfmpc_557_19
Popis: Purpose: The present study aimed to evaluate refractive error and axial length changes after buckle removal due to buckle complications. Methods: A total of 15 patients involved in this study. The enrolled patients who had history of scleral buckling (SB) for rhegmatogenous retinal detachment referred to clinic for buckle removal due to buckle-related complications. Complete ophthalmic examinations and IOLMaster (Carl Zeiss) device performed prior and 3 months after buckle removal. Also best corrected visual acuity (BCVA), refractive error and axial length changes evaluated after buckle removal. Results: BCVA, refractive error, and axial length changes were not statistically significant (P value: 0.24, 0.23, 0.33, respectively). No redetachment or any other complication was observed after buckle removal. Conclusion: The study displayed induced globe shape changes due to SB are irreversible after buckle removal. In addition, it is a safe procedure and does not raise any risk of retinal redetachment.
Databáze: Directory of Open Access Journals