Popis: |
The high-speed Maglev train is driven by long-stator linear synchronous motors (LLSM). During the long-time outdoor operation, the insulation material of the armature winding may be damaged, either due to aging or the movement of the windings. This may result in the three-phase short-circuit fault, which affects the traction performance and the operation of the train. In this paper, a simulation model of the high-speed Maglev train traction system with a three-phase short-circuit fault LLSM is established, including the converters at two ends, feeder cables, segmented LLSM and traction control system. The system adopts a double-end power supply mode. The model divides the fault segment LLSM into two parts. One part is connected to the converter, which is equivalent to a normal operating segment with shortened long-stator. The other part is equivalent to a three-phase short-circuit linear generator. Based on this model, the influence of running speed and fault segment length on the traction performance of the train is simulated. In addition, the stator current, acceleration and traction force of the Maglev train during fault segment are investigated in the acceleration phase, deceleration phase and constant speed phase, respectively. The results can provide a reference for three-phase short-circuit fault diagnosis. |