Popis: |
Background: To evaluate different adhesive luting procedures on coronal dentin bond-strength of Cerasmart CAD-CAM blocks with μTBS test. Methods: 36 molar crowns were flattened in order to expose sound dentin and a standardized smear layer was created with 600 grit paper. Specimens were divided into six groups according to the luting cement employed (n = 12 each): G1: Panavia V5 (Kuraray, Japan); G2: Bifix QM (Voco, Germany); G3: Estecem (Tokuyama, Japan). CAD-CAM blocks (Cerasmart, GC), shade A2LT, size 14, were sectioned with a diamond saw to obtain 4 mm high specimens, which were then luted on the coronal dentin, following the manufacturer instructions. Specimens were serially sectioned to obtain 1 mm thick beams in accordance with the μTBS test technique. Half of the beams were stressed to failure after 24 h (t = 0), while the other half were stored in artificial saliva for 12 months, at 37 °C, for ageing before stressing to failure (t = 12). Results: two-way ANOVA test showed significant difference for the factor “luting cement” (p = 0.0002), while the factor “time of storage” (p = 0.0991) had no significant effect on µTBS. Conclusions: PanaviaV5 seems to have better µTBS values at T0 than QM and ES and 1 year aging doesn’t seem to affect the bonding strength of tested systems. |