Autor: |
Wael Hamza Kamr, Mohamed Gaber Eissawy, Amr Saadawy |
Jazyk: |
angličtina |
Rok vydání: |
2020 |
Předmět: |
|
Zdroj: |
The Egyptian Journal of Radiology and Nuclear Medicine, Vol 51, Iss 1, Pp 1-6 (2020) |
Druh dokumentu: |
article |
ISSN: |
2090-4762 |
DOI: |
10.1186/s43055-020-00348-2 |
Popis: |
Abstract Background Early diagnosis of meningitis with magnetic resonance imaging (MRI) would be useful for appropriate and effective management, decrease morbidity and mortality, and provide better diagnosis and treatment. The objective of the current study is to compare the accuracy of contrast-enhanced FLAIR (CE-FLAIR) and contrast-enhanced T1WI (CE-T1WI) in the detection of meningeal abnormalities in suspected cases of meningitis. Results Out of 45 patients, 37 patients were confirmed to have meningitis on CSF analysis. Out of the 37 patients, 34 patients were positive on CE-FLAIR sequence and 27 were positive on CE-T1WI. The sensitivity of CE-FLAIR sequence was 91.9% and specificity 100%, while the sensitivity of CE-T1WI sequence was 73% and specificity 100%. Conclusion CE-FLAIR is more sensitive than CE-T1WI in diagnosis of meningitis. It is recommended to be used in any cases with clinically suspected meningitis. |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|