High resolution MCP-PMT Readout Using Transmission Lines

Autor: Follin, M., Chyzh, R., Sung, C. -H., Breton, D., Maalmi, J., Chaminade, T., Delagnes, E., Schäfers, K., Weinheimer, C., Yvon, D., Sharyy, V.
Rok vydání: 2021
Předmět:
Druh dokumentu: Working Paper
DOI: 10.1016/j.nima.2021.166092
Popis: We study the potential of the MCP-PMT read-out to detect single photo-electron using transmission lines. Such a solution limits the number of read-out channels, has a uniform time resolution across the PMT surface and provides quasi-continuous measurement of the spatial coordinates. The proposed solution is designed to be used in the BOLD-PET project aiming to develop an innovative detection module for the positron emission tomography using the liquid detection media, the tri-methyl bismuth. In this study we use the commercial MCP-PMT Planacon from Photonis, with 32x32 anode structure. The PCB gathers signals from anode pads in 32 transmission lines which are read-out from both ends. Amplifier boards and SAMPIC modules, developed in our labs, allow us to realize the cost-effective, multi-channel digitization of signals with excellent precision. For a single photo-electron, we measured a time resolution of 70~ps (FWHM) simultaneously with a spatial accuracy of 1.6~mm and 0.9~mm (FWHM) along and across transmission lines correspondingly.
Comment: Accepted by Nuclear Instruments and Methods in Physics Research Section A
Databáze: arXiv