High-rate glass MRPC for fixed target experiments at Nuclotron
Autor: | Kuzmin, N. A., Ladygin, E. A., Ladygin, V. P., Petukhov, Yu. P., Sychkov, S. Ya., Semak, A. A., Ukhanov, M. N., Usenko, E. A. |
---|---|
Rok vydání: | 2018 |
Předmět: | |
Druh dokumentu: | Working Paper |
DOI: | 10.1016/j.nima.2018.11.098 |
Popis: | A Multi-gap Resistive Plate Chamber (MRPC) equipped with heaters to improve the counting rate capability was designed for the BM@N experiment in Dubna. The measurements were performed using a muon beam at IHEP U-70 accelerator in Protvino. The MRPC at 40$^0$C tolerates counting rate up to 6 kHz/cm$^2$ with time resolution ~65 ps and efficiency ~95\% which complies with the conditions of the experiment. Comment: 7 pages, 13 figures |
Databáze: | arXiv |
Externí odkaz: |