Installation Progress At The PIP-II Injector Test At Fermilab

Autor: Baffes, C., Alvarez, M., Andrews, R., Chen, A., Czajkowski, J., Derwent, P., Edelen, J., Hanna, B., Hartsell, B., Kendziora, K., Mitchell, D., Prost, L., Scarpine, V., Shemyakin, A., Steimel, J., Zuchnik, T., Edelen, A.
Rok vydání: 2017
Předmět:
Druh dokumentu: Working Paper
Popis: A CW-compatible, pulsed H- superconducting linac "PIP-II" is being planned to upgrade Fermilab's injection complex. To validate the front-end concept, a test accelerator (The PIP-II Injector Test, formerly known as "PXIE") is under construction. The warm part of this accelerator comprises a 10 mA DC, 30 keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1 MeV Radio Frequency Quadrupole (RFQ) capable of operation in Continuous Wave (CW) mode, and a 10 m-long Medium Energy Beam Transport (MEBT). The paper will report on the installation of the RFQ and the first sections of the MEBT and related mechanical design considerations.
Comment: 4 pp