Autor: |
Ushie, P. O., Nwankwo, Victor U. J., Bolaji, Ayinmode, Osahun, O. D. |
Rok vydání: |
2013 |
Předmět: |
|
Zdroj: |
IOSR Journal of Applied Physics (IOSR-JAP), e-ISSN: 2278-4861. Volume 3, Issue 6, 2013, pp 17-21 |
Druh dokumentu: |
Working Paper |
Popis: |
We present the result of a preliminary assessment of radio-frequency radiation exposure from selected mobile base stations in Ajaokuta environs. The Power density of RF radiation within a radial distance of 125m was measured. Although values fluctuated due to the influence of other factors, including wave interference from other electromagnetic sources around reference base stations, we show from analysis that radiation exposure level is below the standard limit (4.5W/sqm for 900MHz and 9W/sqm for 18000MHz) set by the International Commission on Non-ionizing Radiation Protection (ICNIRP) and other regulatory agencies. |
Databáze: |
arXiv |