Використання складових миттєвої потужності при локальному тестуванні шихтованих осердь статорів синхронних двигунів індукційним методом

Jazyk: ukrajinština
Rok vydání: 2021
Předmět:
Zdroj: Reporter of the Priazovskyi State Technical University. Section: Technical sciences; No. 42 (2021): Reporter of the Priazovskyi State Technical University. Section: Technical sciences; 122-129
Вестник Приазовского государственного технического университета. Серия: Технические науки; № 42 (2021): Вестник ПГТУ. Серия: Технические науки; 122-129
Вісник Приазовського Державного Технічного Університету. Серія: Технічні науки; № 42 (2021): Вісник ПДТУ. Серія: Технічні науки; 122-129
ISSN: 2225-6733
2519-271X
DOI: 10.31498/2225-6733.42.2021
Popis: The problem of long-term operation of synchronous motors consists in the deterioration of the properties of the main indispensable structural units, among which stator laminated cores should be noted first of all. Their main damage, such as short circuiting of individual sheets of electrical steel of the core and weakening of compression, cause a redistribution of its electrical and magnetic properties. As a result, it causes anomalies in the growth of steel losses in local areas of the core, which entails local overheating of the stator winding, and, in the case of high-power synchronous motors, can lead to mechanical and thermomechanical destruction of the core as a whole. Various methods are used to determine the location of such anomalies, among which local induction is the most promising one. Their use is limited by the low probability of such diagnostics, primarily due to the lack of a sufficient number of independent diagnostic parameters to distinguish the main types of damage to the laminated cores depending on their location. The results of previous research determine the prospects for the use of instantaneous power components as diagnostic parameters. However, there is no research on the application of such parameters in real modes of local diagnosis when the conditions of its implementation change. With solving this problem, the paper contains the description of the improved method of the use of power components as diagnostic parameters at local induction testing of the cores of synchronous motor stators. The ways to improve their informativeness, stability and reliability with the change of the degree of saturation of the magnetic system, frequency and distance between the inductor and the teeth of the cores, which determine the real modes of their diagnosis, are specified
У роботі вдосконалено метод використання складових миттєвої потужності у якості діагностичних параметрів при локальному індукційному тестуванні осердь статорів синхронних двигунів. Обумовлено шляхи покращення їх інформативності, стійкості та вірогідності при зміні ступеня насичення магнітної системи, частоти та відстані між індуктором та зубцями осердь, що обумовлюють реальні режими їх діагностики
Databáze: OpenAIRE