Comparison of the diagnostic accuracy of cone beam computed tomography and radiography for scaphoid fractures

Autor: Jakob, Neubauer, Matthias, Benndorf, Claudia, Ehritt-Braun, Kilian, Reising, Tayfun, Yilmaz, Christopher, Klein, Horst, Zajonc, Elmar, Kotter, Mathias, Langer, Sebastian Moritz, Goerke
Jazyk: angličtina
Rok vydání: 2018
Předmět:
Zdroj: Scientific Reports, Vol 8, Iss 1, Pp 1-6 (2018)
Scientific Reports
ISSN: 2045-2322
DOI: 10.1038/s41598-018-22331-8
Popis: The aim of this study was to evaluate and compare the diagnostic accuracy, the inter-rater agreement and raters’ certainty of cone beam computed tomography (CBCT) and radiography for the detection of scaphoid fractures. Our hypothesis is that the CBCT has a higher diagnostic accuracy for scaphoid fractures than radiography. We retrospectively analysed patients who underwent both radiography and CBCT examinations within 4 days to rule out a scaphoid fracture over a 2-year period in our institution. 4 blinded radiologists and orthopaedic surgeons independently rated the images regarding the presence of a scaphoid fracture. The reference standard was evaluated by two radiologists in a consensus reading. Inter-rater correlation was evaluated, pooled sensitivity, specificity, positive and negative predictive values were calculated and compared. 102 patients met the inclusion criteria. 52% of them had a scaphoid fracture. The inter-rater correlation was higher in the CBCT compared to radiography (P