Autor: |
V, Menon, A, Bansal, P, Prakash |
Jazyk: |
angličtina |
Rok vydání: |
1997 |
Předmět: |
|
Zdroj: |
Indian Journal of Ophthalmology, Vol 45, Iss 3, Pp 169-171 (1997) |
ISSN: |
0301-4738 |
Popis: |
Binocular combinations of Snellen acuity were varied from 6/60 to 6/6 in standard steps in twenty normal adults and Randot stereoacuity was measured at each level. Using the 560 unique stereoacuity scores thus obtained, a nomogram was constructed which provides expected stereoacuity scores at all unique binocular combinations of Snellen acuity. It was seen that there is a linear correlation between binocular isoacuity (at level 6/36 or better) and Randot stereoacuity. |