Popis: |
Lesion length has been an important factor in predicting a worse outcome after percutaneous coronary interventions (PCI); however, the safety and efficacy of second-generation drug eluting stents in very long coronary lesions has not been validated in large scale randomized controlled trials.We performed a patient level pooled analysis of 13,266 patients undergoing planned overlapping stent treatment of very long coronary lesions with the XIENCE V everolimus eluting coronary stent system from 6 trials evaluating the XIENCE V stent (Spirit II, III, IV, V, Spirit Small Vessel and XIENCE V USA). Patients were divided into two cohorts, a very long lesion (VLL) group (lesions ≥35 mm) and a control group (lesions24 to35 mm). The primary outcome measures were Target Lesion Failure (TLF), Major Adverse Cardiac Events (MACE), and Academic Research Consortium (ARC) defined definite and probable stent thrombosis at 1 year.A total of 13,266 patients were included in the pooled analysis of which 2.4% (323 patients with 328 total lesions) had a mean lesion length of 47.1 ± 13.7 mm in the VLL group which were compared to controls comprised of 3.6% of the cohort (482 patients with 500 total lesions) with mean lesion length of 28.1 ± 2.4 mm.There was no significant difference in the rates of TLF between the VVL and control groups (8.9 vs. 10%, P = 0.63), MACE (9.2 vs. 10%, P = 0.74) or stent thrombosis (1.6 vs. 1.5%, P = 0.92) at 1 year.In the treatment of very long coronary lesions, the XIENCE V stent appears as safe and effective as percutaneous coronary interventions for long lesions. © 2016 Wiley Periodicals, Inc. |