Autor: |
G R, Saparoff, T, Chaudhuri, K D, Dolan, J H, Christie |
Rok vydání: |
1976 |
Předmět: |
|
Zdroj: |
Transactions. Section on Ophthalmology. American Academy of Ophthalmology and Otolaryngology. 81(4 Pt 1) |
ISSN: |
0161-6978 |
Popis: |
The lacrimal drainage systems of 78 eyes were studied by technetium scanning at the University of Iowa and, of these, 25 were also subjected to conventional contrast dacryocystography. Twenty-six eyes were asymptomatic for epiphora and normal scans were recorded on all of them. All of the remaining 52 symptomatic eyes had an abnormal lacrimal scan with either a presac or a postsac blockage. In general, there was good correlation with dacryocystography, with the exception of three cases of functional block which had a normal dacryocystogram. Technetium scanning should serve as a valuable tool for diagnosing and localizing lacrimal obstruction. |
Databáze: |
OpenAIRE |
Externí odkaz: |
|