Popis: |
The purpose of this study was to systematically investigate the performance of different radiographic views in the identification of scaphoid fractures in children.This case-control study compared 4-view radiographic examinations of the wrist between children with scaphoid fracture and age- and sex-matched children without fractures performed between January 2008 and July 2019. After randomization, each examination was reviewed 3 times, at least 1 week apart, first using each view separately and later using multiple views without (3-view) and with the posteroanterior (PA) scaphoid view (4-view), to determine the presence or absence of a scaphoid fracture. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated with inter-rater agreement.The study group of 58 children (48 boys and 10 girls; mean age 13.1 ± 2.1 years) included 29 with scaphoid fractures (8 corner, 9 distal pole, 10 waist, and 2 proximal pole) and 29 without fractures. Multiple views had higher sensitivity (3-view, 93.0%; 4-view, 96.5%) for fracture identification when compared to individual views (41.0-89.6%). The oblique view was 100% specific for the identification of a scaphoid fracture, but it lacked sensitivity. The PA scaphoid view had the highest sensitivity (89.6%) and NPV (90%) when compared to other individual views and its inclusion in the 4-view examinations produced the highest inter-rater agreement (93%, κ = 0.86).Multiple radiographic views of the wrist with the inclusion of a PA scaphoid view (4-view) produced the highest sensitivity, NPV, and inter-rater agreement for the identification of a scaphoid fracture in children. |