Analysis of cardiac diastolic function: application in coronary artery disease

Autor: T R, Miller, K J, Goldman, K S, Sampathkumaran, D R, Biello, P A, Ludbrook, B E, Sobel
Rok vydání: 1983
Předmět:
Zdroj: Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 24(1)
ISSN: 0161-5505
Popis: Separation of systolic and diastolic parameters in gated cardiac blood-pool imaging (RVG) was achieved with the retention of two harmonics in the Fourier-series representation of the time-activity curve. Regional and global analysis of left-ventricular peak filling rate (PFR) and time to peak filling (TPF) was performed in 18 control subjects, 20 patients with coronary artery disease (CAD) but with normal RVG (normal regional wall motion and ejection fraction, and 16 CAD patients with abnormal RVG. In regional analysis of CAD patients, the standard deviation of the TPF histogram identified 13/20 (65%) of normal RVG patients and 12/16 (75%) of abnormal RVG patients as abnormal. In global analysis of CAD patients, PFR values identified 10/20 (50%) of normal RVG patients and 11/16 (69%) of abnormal RVG patients as abnormal. Thus, left-ventricular systolic and diastolic parameters can be separately measured with retention of higher-order harmonics in the Fourier transform, and regional inhomogeneity of diastolic filling can be detected in CAD patients with normal resting ejection fraction and wall motion.