1-year clinical outcomes of diabetic patients treated with everolimus-eluting bioresorbable vascular scaffolds: a pooled analysis of the ABSORB and the SPIRIT trials
Autor: | Takashi, Muramatsu, Yoshinobu, Onuma, Robert-Jan, van Geuns, Bernard, Chevalier, Tejas M, Patel, Ashok, Seth, Roberto, Diletti, Hector M, García-García, Cécile C, Dorange, Susan, Veldhof, Wai-Fung, Cheong, Yukio, Ozaki, Robert, Whitbourn, Antonio, Bartorelli, Gregg W, Stone, Alexandre, Abizaid, Patrick W, Serruys |
---|---|
Rok vydání: | 2013 |
Předmět: |
Male
Sirolimus Clinical Trials as Topic Chi-Square Distribution Time Factors Coronary Thrombosis Incidence Coronary Stenosis Myocardial Infarction Cardiovascular Agents Kaplan-Meier Estimate Middle Aged Prosthesis Design Treatment Outcome Risk Factors Absorbable Implants Humans Female Everolimus Propensity Score Diabetic Angiopathies Aged Follow-Up Studies |
Zdroj: | JACC. Cardiovascular interventions. 7(5) |
ISSN: | 1876-7605 |
Popis: | The aim of this study was to evaluate 1-year clinical outcomes of diabetic patients treated with the Absorb bioresorbable vascular scaffold (BVS).Clinical outcomes of diabetic patients after BVS implantation have been unreported.This study included 101 patients in the ABSORB Cohort B trial and the first consecutive 450 patients with 1 year of follow-up in the ABSORB EXTEND trial. A total of 136 diabetic patients were compared with 415 nondiabetic patients. In addition, 882 diabetic patients treated with everolimus-eluting metal stents (EES) in pooled data from the SPIRIT trials (SPIRIT FIRST [Clinical Trial of the Abbott Vascular XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT II [A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT III [Clinical Trial of the XIENCE V Everolimus Eluting Coronary Stent System (EECSS)], SPIRIT IV Clinical Trial [Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System]) were used for the comparison by applying propensity score matching. The primary endpoint was a device-oriented composite endpoint (DoCE), including cardiac death, target vessel myocardial infarction, and target lesion revascularization at 1-year follow-up.The cumulative incidence of DoCE did not differ between diabetic and nondiabetic patients treated with the BVS (3.7% vs. 5.1%, p = 0.64). Diabetic patients treated with the BVS had a similar incidence of the DoCE compared with diabetic patients treated with EES in the matched study group (3.9% for the BVS vs. 6.4% for EES, p = 0.38). There were no differences in the incidence of definite or probable scaffold/stent thrombosis (0.7% for both diabetic and nondiabetic patients with the BVS; 1.0% for diabetic patients with the BVS vs. 1.7% for diabetic patients with EES in the matched study group).In the present analyses, diabetic patients treated with the BVS showed similar rates of DoCEs compared with nondiabetic patients treated with the BVS and diabetic patients treated with EES at 1-year follow-up. (ABSORB Clinical Investigation, Cohort B; NCT00856856; ABSORB EXTEND Clinical Investigation; NCT01023789; Clinical Trial of the Abbott Vascular XIENCE V Everolimus Eluting Coronary Stent System [SPIRIT FIRST]; NCT00180453; A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System [SPIRIT II]; NCT00180310; Clinical Trial of the XIENCE V Everolimus Eluting Coronary Stent System [EECSS] [SPIRIT III]; NCT00180479; Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System [SPIRIT IV Clinical Trial]; NCT00307047). |
Databáze: | OpenAIRE |
Externí odkaz: |