[Legionnaire's disease outbreak]

Autor: M Pilar, Barrufet-Barqué, Goretti, Sauca-Subias, Lluís, Force-Sanmartín, Angela, Felip-Benach, Encarna, Martínez-Pérez, Josep A, Capdevila-Morell
Rok vydání: 2006
Předmět:
Zdroj: Medicina clinica. 126(5)
ISSN: 0025-7753
Popis: To describe an outbreak of Legionella pneumophila serogroup 1 in Mataró, Catalunya, Spain, in August 2002. The source of the microorganism was a cooling tower.Prospective and observational study with analysis of epidemiological, clinical, and microbiological data.151 patients were affected (62% male), with a mean age of 58.4 years old. Seven patients were classified as Pontiac Fever and 144 suffered from pneumonia. The diagnosis of pneumonia was confirmed in 79% of cases, was considered suspicious in 14% and probable in 7%. Forty per cent of patients were smokers and 53.5% had comorbidities, mainly diabetes mellitus (22%). Chief symptoms were fever (97%), chills and muscular pain (63% respectively), headache (54%) and cough (53%). Pulmonary condensation was the more frequent radiological feature (71%). Normal pulmonary exploration was observed in 38%. Forty-three per cent of cases were severely ill, and 16% of patients belonged to Fine's IV and V class. Antigenuria was the most important test for diagnosis, which confirmed 76% of cases. Legionella spp. was obtained in respiratory secretions of 10 patients. Molecular analysis confirmed clonality between respiratory microorganisms and that obtained in the cooling tower.The outbreak involved an important number of subjects in a short period of time. Antigenuria was the most useful test. However, the isolation of L. pneumophila from patients permitted the prompt identification of microorganism's source in a cooling tower. The low mortality observed probably relates to a rapid diagnosis and its target treatment.
Databáze: OpenAIRE