Blade expandable intramedullary nails for fixation of tibial shaft fractures

Autor: Teoman, Basaran, Murat, Calbiyik, Pınar Özge, Basaran, Ercan, Hassa, Deniz, Ipek
Rok vydání: 2020
Předmět:
Zdroj: Acta orthopaedica Belgica. 85(4)
ISSN: 0001-6462
Popis: This study is aimed to compare the clinical and radiological differences between classic locked intra- medullary nailing (LIN) and blade expandable intra- medullary nailing (BEIN) at tibia shaft fractures. Operation time, exposing of radiation time and fracture healing times were recorded. Pain visual anolog scale (VAS), shortening of tibia and angulation of fracture line were compared. All patients healed. In LIN group operation time, exposing of radiation time was longer (statistically significant). Because of shorter operation time and lower radiation exposure we recommend the BEIN technique as a preferable technique in tibia intramedullary nailing.
Databáze: OpenAIRE