Comparison of technetium-99m and iodine-123 imaging of thyroid nodules: correlation with pathologic findings

Autor: Z, Kusić, D V, Becker, E L, Saenger, P, Paras, P, Gartside, T, Wessler, S, Spaventi
Rok vydání: 1990
Předmět:
Zdroj: Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 31(4)
ISSN: 0161-5505
Popis: Three hundred and sixteen patients with solitary or dominant thyroid nodules were imaged both with technetium-99m- (99mTc) pertechnetate and iodine-123 (123I). The images were preferred, but differences were small and in 27%-58% of the cases there was no difference in quality between the two radionuclides. Discrepancies between 99mTc and 123I images were found in 5%-8% of cases, twice as often in multinodular goiters as in single nodules. Cytologic/histologic examination was performed on all nodules but no correlation was found between the pathology and the type of discrepancy. Twelve carcinomas were found (4%) but none in nodules showing a discrepancy. There was great variation among the observers about the preference for radionuclides and about the existence or type of discrepancies. The slightly better overall quality of 123I scans is probably not of diagnostic significance and does not justify the routine use of 123I instead of 99mTc. Routine reimaging of 99mTc hot nodules with radioiodine for cancer detection does not appear to be necessary.
Databáze: OpenAIRE