Autor: |
O V, Zhulanov, T I, Gromova, S V, Rudakova, R I, Smolianets, E I, Solov'eva |
Rok vydání: |
2002 |
Předmět: |
|
Zdroj: |
Gigiena i sanitariia. (4) |
ISSN: |
0016-9900 |
Popis: |
Spectrometry was used by means of an alpha-radiometer on a [symbol: see text]porpecc-[symbol: see text] hard-and-software complex to study the radioactive contamination of the surfaces of neutralizers with plutonium 239-based ionizing radiation sources, which are employed to remove electrical charges from electrifiable materials. While using the neutralizers, the operating personnel is shown to be exposed to radiation. The level of removed radioactive contamination during half-a-year exploitation of the neutralizers was greater than the maximum allowable values on the average by several times. Radiation hazard in the use of radioisotopic neutralizers of static electricity is outlined. |
Databáze: |
OpenAIRE |
Externí odkaz: |
|