Popis: |
A hypothermia and rewarming system combining body surface and ventilatory heat exchange is described. The method utilizes body surface heat exchange through conduction, convection, and black body radiation, and ventilatory heat exchange across the lung surface through conduction, convection, and water evaporation. The system consisted of a chamber in which the temperature was maintained at a desired level (+/- 2.5 degrees C) using a refrigeration-heat pump unit. Chamber temperatures during cooling and rewarming were -15.5 +/- 2.7 degrees C and 43.2 +/- 2.3 degrees C, respectively. Inhalate temperatures during cooling were -8.2 +/- 6.5 degrees C and during rewarming they were 41.5 +/- 0.3 degrees C. Helium (100%) was supplied to the chamber, while the animal was ventilated with 20% O2 + 80% He. Under these conditions, the cooling and rewarming rates were 0.33 +/- 0.06 degrees C/min and 0.20 +/- 0.04 degrees C/min, respectively, at 38--21 degrees C. The system provided for rapid cooling and rewarming with no evidence of any untoward effects. |