Graft Suturing for Lenticule Dislocation after Descemet Stripping Automated Endothelial Keratoplasty

Autor: Wu, Wai-Kwan, Wong, Victoria W Y, Chi, Stanley C C
Jazyk: angličtina
Rok vydání: 2011
Předmět:
Zdroj: Journal of Ophthalmic & Vision Research
ISSN: 2008-322X
2008-2010
Popis: Purpose To report the mid-term outcomes of graft suturing in a patient with lenticule dislocation after Descemet stripping automated endothelial keratoplasty (DSAEK). Case Report A 78-year old woman was found to have graft dislocation involving the nasal half of the cornea after uneventful DSAEK. Graft repositioning, refilling the anterior chamber with air, and placement of four full-thickness 10/0 nylon sutures over the detached area were performed two weeks after the initial surgery. The sutures were removed 6 weeks later. Serial specular microscopy and anterior segment optical coherence tomography were performed. At 18 months, there was good lenticule apposition and a clear graft. Conclusion Anchoring sutures seem to be effective for management of graft detachment following DSAEK.