Evaluation of a needle-free injection system for local anaesthesia prior to venous cannulation

Autor: J A, Cooper, L M, Bromley, A P, Baranowski, S G, Barker
Rok vydání: 2000
Předmět:
Zdroj: Anaesthesia. 55(3)
ISSN: 0003-2409
Popis: We evaluated a single-use, disposable, carbon-dioxide-powered, needleless injector (J-Tip, National Medical Products Inc., CA, USA), which is claimed to deliver a virtually painless, subcutaneous injection. Seventy-two patients undergoing various types of surgery had a large-bore intravenous cannula inserted prior to induction of general anaesthesia. Three minutes beforehand, a subcutaneous injection of 0.3 ml of 1% plain lidocaine was administered. Subjects were randomly allocated to receive the lidocaine either by the needleless injector or from a conventional syringe and a 25 G needle. Pain scores were recorded on injection of the lidocaine and on insertion of the cannula. There was significantly less pain on injection with the needleless injector than with the 25 G needle (p0.001) but, surprisingly, there was more pain on cannulation (p0. 001). We conclude that the device certainly delivers a less painful subcutaneous injection than a 25 G needle, but perhaps provides less effective skin anaesthesia for venous cannulation at sites where the subcutaneous space is small; its use might be better suited to areas where the subcutaneous space is deeper.
Databáze: OpenAIRE