Popis: |
Between February 1988 and May 1989, 17 consecutive patients with 18 tibial fractures were treated using the Ilizarov method and apparatus. Injuries included four closed fractures and 14 open fractures. There were three Grade I open, four Grade II open, and seven Grade III open tibial fractures. Indications for application of the Ilizarov frame included fractures that were determined to need surgical management primarily, or fractures that had failed to heal by other treatment methods, either operative or nonoperative. Patients averaged 17.7 months of follow-up treatment. One patient was lost to follow-up treatment after the fracture healed and the device was removed. To date, all fractures are healed. There was one delayed union, which subsequently healed with a second application of the device. Complications included two late wound infections, both in Grade III open fractures. These occurred after removal of the Ilizarov apparatus. The average time from application of the device to complete fracture healing was 5.6 months, with a range of 3.25 to 13 months. This compares favorably with the results described for other treatment modalities. These results indicate that the Ilizarov method is indeed a useful adjunct in the orthopedic armamentarium for the treatment of either open or closed tibial fractures. No practical contraindications to the use of the Ilizarov device in the management of tibial fractures were encountered. |