Autor: |
H, Köhn, B, König, H, Klech, W, Pohl, A, Mostbeck |
Rok vydání: |
1990 |
Předmět: |
|
Zdroj: |
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 31(4) |
ISSN: |
0161-5505 |
Popis: |
Technetium-99m DTPA clearance (99mTc-DTPA) clearance measured by a gamma camera or a scintillation probe not only reflects epithelial transport, but is also influenced by an unknown amount of mucociliary clearance depending on particle size and aerosol deposition. This is confirmed by factor analysis of dynamic inhalation studies. Assessment of epithelial absorption by urinary excretion of inhaled 99mTc-DTPA is largely independent of aerosol lung deposition. Twenty-four-hour excretion reflects the amount of aerosol cleared by absorption, while two-hour excretion is a quantitative measure of the aerosol absorption rate from the epithelium into blood. Urinary 99mTc-DTPA excretion of two aerosols with different particle size correlated significantly (p less than 0.001) with analysis of lung clearance curves. A very similar regression in the form of a cumulative exponential function was found with both aerosols. Two-hour urine values of nonsmokers differed significantly from those of smokers or patients with active interstitial or infectious lung disease. This alternative procedure is suited as a bedside test and holds promise for patient monitoring and follow-up. |
Databáze: |
OpenAIRE |
Externí odkaz: |
|