Is a Proactive Approach to Controlling

Autor: Daniela, Glažar Ivče, Dobrica, Rončević, Marina, Šantić, Arijana, Cenov, Dijana, Tomić Linšak, Vladimir, Mićović, Dražen, Lušić, Marin, Glad, Davor, Ljubas, Darija, Vukić Lušić
Rok vydání: 2020
Předmět:
Zdroj: Food Technology and Biotechnology
ISSN: 1330-9862
Popis: SUMMARY Research background Legionella are Gram-negative bacteria that are ubiquitous in the natural environment. Contaminated water in man-made water systems is a potential source of transmission of legionnaires’ disease. The aim of this study is to explore the prevalence of Legionella pneumophila in the drinking water distribution system (DWDS) of Primorje-Gorski Kotar (PGK) County, Croatia, for the period 2013-2019, coupled with the incidence of legionnaires’ disease. A number of L. pneumophila-positive samples (>100 CFU/L), serogroup distribution and the degree of contamination of specific facilities (health and aged care, tourism, and sports) were assessed. Based on the obtained results, the reasoning for the implementation of a mandatory Legionella environmental surveillance program was assessed. Experimental approach Sample testing for Legionella was carried out according to the standard method for enumeration of this bacterium. A heterotrophic plate count (HPC) and Pseudomonas aeruginosa number were analysed along with the basic physicochemical indicators of drinking water quality. The research period was divided into two parts, namely, the 2013-2018 period (before implementation of the prevention program, after the outbreak of legionnaires’ disease), and the year 2019 (proactive approach, no disease cases recorded). Results and conclusion During the 7-year observation period in PGK County, an increase in the number of samples tested for Legionella was found. An increase in Legionella-positive samples (particularly pronounced during the warmer part of the year) was recorded, along with a growing trend in the number of reported legionnaires’ disease cases. In addition to hot water systems, the risk of Legionella colonisation also applies to cold water systems. Health and aged care facilities appear to be at highest risk. In addition to the higher proportion of positive samples and a higher degree of microbiological load in these facilities, the highest proportion of L. pneumophila SGs 2-14 was identified. Due to the diagnostic limitations of the applied tests, the number of legionnaires’ disease cases is underdiagnosed. Novelty and scientific contribution The introduction of a mandatory preventive approach to monitoring Legionella in DWDS water samples, along with the definition of national criteria for the interpretation of the results will create the preconditions for diagnosis and adequate treatment of larger numbers of legionnaires’ disease cases.
Databáze: OpenAIRE